| Home | About Us | Contact Us | Support | Search | | Facility | | PBO | Education & Outreach | ||
![]() |
![]() |
|||||||
|
Project Support Polar Services What's New Remote Station Engineering GPS Support LiDAR Support Geodetic Data GPS Base Stations Reports Polar Links |
Polar Services - Remote Station Engineering - Power Draw Profile for Trimble NetRS and Iridium System
POWER DRAW PROFILE FOR TRIMBLE NetRS AND IRIDIUM SYSTEMTest SummaryUNAVCO performed a benchtop test to record a high-resolution time history of power consumed by a Trimble NetRS GPS system with Iridium communications. The test system consisted of a Trimble NetRS receiver with Trimble Choke Ring antenna, NAL Research A3LA-I modem with SAF5350C antenna, Flexcharge NC30L12 solar regulator, and an ABB RS1A44 timer switch. This system represents the UNAVCO best-practices polar GPS station as of June 2006. The test was performed at room temperature. A variable DC power supply was used to deliver 12.0 VDC to the battery input terminals on the power board, with current and voltage recorded at 10 Hz by a data acquisition computer running LabView. The data acquisition routine clipped the current burst signals above 1 amp (12 W) during Iridium data download, however this threshold was usually close to the true peak height of the ~0.1 second pulses. For longer duration, stronger bursts, a conservative visual estimation of the true peak height was made and used in calculating the power consumption during data download. Test Sequence: 1. Power full system with 12.0 VDC. 2. Allow components to boot up and assume steady-state operation. 3. Disconnect Iridium modem for 1 minute. 4. Reconnect Iridium modem and allow system to return to steady-state operation. 5. Execute Iridium download script: call Iridium modem and download small GPS data file. 6. Call was dropped. 7. Iridium download script redials and second call is initiated. Call is user-terminated. 8. Turn off entire system. Disconnect Iridium modem. 9. Turn on system and allow system to reboot and assume steady-state operation (w/o Iridium). 10. Disconnect power.
Results
The measured power draw time series is presented in the figure below.
Last modified Thursday, 01-May-2008 21:27:06 UTC |
|
![]() |
Home | About Us | Contact Us | Support | Search | Facility | PBO | Education & Outreach Comments: webmaster |
|