UNAVCO Home UNAVCO Home
   |    |   |  
UNAVCO Home UNAVCO Facility

Software Remote PC Software RedHat Linux Auxiliary utilities Downloading & Data Transfer AOA Ashtech Trimble Other Pre-Processing TEQC Other Processing GAMIT/GLOBK Bernese GIPSY-OASIS II Trimble Geomatics (TGO)
Bernese - Frequently Asked Questions

Question

I start the PCS from the menu system, but it just returns to the menu panel without running.

Answer

There is probably a problem in the PCF. You will need to run the PCS manually, and find the problem. See the Bernese manual secion 21.6.6 for details on command line processing. The command sequence would look something like this.
[braunjizu braunj]$ cd $U/WORK
[braunjizu WORK]$ PCS DOCU40_1 CAMP DOCU40_1 SES 1650 YR 96
 LINE:  10 FILE: DOCU40_1.PCF   PID OF 000 NOT ALLOWED
  BAD RETURN CODE FROM CKPCF
PCS: ..................................................
PCS: :
PCS: : RUN_PCF check/clear failed!
PCS: :.................................................

The error message then needs to be interpreted and fixed. In the above example, the PCF has a procedure defined as 000. This needs to be fixed before the BPE will run any further.
Return to the FAQ index page.

Last modified Thursday, 17-Nov-2005 03:58:00 UTC

 